Zum Wired J-Box Load Controller, 0-10V Dimmer, 16A, 100-277V with Net and Link Communication
Model: ZUMNET-JBOX-16A-LV
- Zum® wired junction box-mounted lighting load dimmer
- Dimming control of 0-10V LED drivers or 4-wire fluorescent ballasts
- Integration with Zum keypads, occupancy sensors, vacancy sensors, and daylight sensors (sold separately)
- Ethernet network connection to a control system (sold separately)
- Integrated contact closure input
The Crestron Zum® Wired ZUMNET?JBOX?16A?LV provides 0?10V dimming for drivers and ballasts. The device can be wired to Zum Net devices for network expansion and to Zum Link devices for in?room control. Energy-saving options are available to enable daylighting, occupancy or vacancy sensing, and centralized monitoring and management.
Zum Net Wired Technology
In a Zum network, ZUMNET?JBOX devices facilitate communications between rooms via ethernet and can be daisy?chained for network expansion. Each device in the chain communicates to a control system for centralized monitoring, management, and reporting. Zum Link devices connect to ZUMNET-JBOX devices to provide in?room lighting control. Similar to the Zum Wireless system, Zum Link devices work together in a local ecosystem to provide customized solutions as needed.
Easy Installation
For flexibility and ease?of?use, Zum load controllers are installed in a room with Zum keypads, occupancy or vacancy sensors, and/or a daylight sensor for complete commercial lighting control. Finish the installation by quickly commissioning the room through the Zum app.
Override Contact Closure Input
An integrated contact closure input or relay output on the ZUMNET?JBOX?16A?LV provides the means to place all connected Zum Net and Zum Link devices into Emergency Override mode.
- Zum® wired junction box-mounted lighting load dimmer
- Dimming control of 0-10V LED drivers or 4-wire fluorescent ballasts
- Integration with Zum keypads, occupancy sensors, vacancy sensors, and daylight sensors (sold separately)
- Ethernet network connection to a control system (sold separately)
- Integrated contact closure input
- Flying lead wiring connections
- Knockout mount to a standard 4 in. square junction box
- Spec Sheet available - Yes
- Certifications: IC, FCC, cUL, UL
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- AC Voltage (Minimum): 100 Volts
- AC Voltage (Maximum): 277 Volts
- Current Draw: 16 Amps
- Depth: 2.03 in
- Height: 4.83 in
- Width: 4.25 in
- Product Weight: 0.44 lbs
- Color: White
- Load Control:
•Dim Load Types: 0-10V LED drivers or electronic ballasts (4-wire)
•Switch Load Types: LED, electronic ballasts, incandescent, magnetic low-voltage, electronic lowvoltage,neon/cold cathode, high-intensity discharge, small motor loads
•Dim Control Output: 0-10VDC, 60mA maximum sink or source
•Short Circuit : Protection 40A non-replaceable fuse - Wired Communications:
•ZUMNET (LAN): (2) RJ-45 ports; Input for control system connection or Zum Net device; Output for Zum Net device daisy-chaining
•ZUMLINK (ROOM): (2) RJ-45 ports; In-room Zum Link device daisy-chaining; 85mA power available for Zum Link devices, including ZUMLINK-KP keypads
•24V, OCC, GND: Occupancy sensor input; 85mA available output current; Spring clamp connector
•24V, PHO, GND: Photo sensor input; Spring clamp connector
•OVR, GND: Override control input; Spring clamp connector - Controls and Indicators:
•TEST: (1) Pushbutton and (1) green LED; Push to toggle the switched load output on and off; Press and hold to cycle the dimming level up and down; LED indicates that the load is turned on; LED lights and flashes during room setup and factory reset
•ZUMLINK Status: (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected
•ZUMNET Status: (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected - Connections:
•Hot: (1) 14 AWG Class 1 flying lead; Black, line power input
•Neutral: (1) 14 AWG Class 1 flying lead; White, neutral
•Red: (1) 14 AWG Class 1 flying lead, red, AC output
•Purple: (1) 18 AWG Class 1 flying lead, purple, 0-10VDC dimming control output, positive
•Gray: (1) 18 AWG Class 1 flying lead, gray, 0-10VDC dimming control output, negative - Humidity: 10% to 90% RH (noncondensing)
- Construction:
•Housing: Plastic, white, UL 94 5VA flame rated
•Mounting: Mounts to the side of a 4 in. square junction box via a 1/2 in. conduit knockout; Meets the requirements of UL 2043 for installation in an environmental air-handling (plenum) space
TRITECH Communications
625 Locust Street, Suite 300
Garden City, NY 11530
USA
(631) 254-4500
www.tritechcomm.com